The Bosch Rexroth Indramat VT1600 is a servo amplifier from the VT1600 series, designed for controlling servo valves without LVDT feedback in closed-loop applications. Amplifiers without a voltage regulator require a ±15 Volts DC supply, while those with one need ±22 to ±28 Volts DC. The current consumption is less than 200 milliamps, with an internal control voltage range of 0 to ±10 Volts DC and produced output current of ±60 milliamps/±100 milliamps. The amplifier, presented in a Euro card format, measures 100 x 160 millimeters and weighs approximately 0.15kg. Designed for a 0-50 degrees Celsius working temperature and a -20 to 70 degrees Celsius storage range, it can be easily operated with precautions and proper training. The VT1600 is equipped with an ammeter on its front panel for monitoring the output current.
30 Day Warranty
Technical Specifications
  • Manufacturer: Bosch Rexroth Indramat
  • Product Series: VT1600
  • Product Type: Servo Amplifier
  • Designed for: Controlling servo valves without LVDT feedback
  • Applications: Closed-loop
  • Voltage Requirements without Regulator: ±15 Volts DC
  • Voltage Requirements with Regulator: ±22 to ±28 Volts DC
  • Current Consumption: less than 200 milliamps
  • Internal Control Voltage Range: 0 to ±10 Volts DC
  • Output Current: ±60 milliamps/±100 milliamps
  • Typical Dither Current: 340 Hertz
  • Format: Euro card
  • Installing Method: Card holder or Euro magazine
  • Front Plate Dimensions: 128 x 5 millimeters
  • Main Circuit Board Dimensions: 100 x 160 millimeters
  • Relay Coil Resistance: 2000 Ohms nominal
  • Relay Duty cycle: 1 millisecond
  • Relay Coil Voltage: 22 to 28 Volts DC
  • Recommended Ambient Temperature Range: 0 to 50 degrees Celsius
  • Recommended Storage Temperature Range: -20 to 70 degrees Celsius
  • Weight: 0.15 kilograms
  • Ammeter Provided: Yes
  • Operational Precautions: Power off before connecting or disconnecting; No use of radio transmitters within 3 feet; Measurements should be made with high impedance meter; Input signal switches should handle currents less than 1 milliamp
  • Required for Operation: Proper training and experience.