Indramat VT-3000 amplifiers are utilized across various industrial applications to ensure precise and reliable control of machinery and processes. These amplifiers play a crucial role in driving motors and controlling their speed, torque, and position with high accuracy. Their robust design and advanced features make them suitable for demanding environments where consistent performance is essential. Whether in manufacturing, automation, or robotics, the VT-3000 amplifiers excel in providing efficient and dependable control solutions, contributing to increased productivity and operational efficiency.

The Indramat VT-3000 amplifiers are designed for precision control in industrial settings, offering robust performance under varying environmental conditions. These amplifiers operate effectively within a permissible ambient temperature range of 0 to 55 °C when equipped with a fan for enhanced cooling. During operation, they can withstand relative humidity levels between 20% and 90% without condensation, ensuring reliable functionality in diverse operational environments. For storage, the amplifiers can endure temperatures ranging from -20 °C to 70 °C, with relative humidity tolerances spanning from 20% to 95%. Classified as Protection Class I devices, they provide IP20-rated protection against accidental contacts when properly installed, ensuring safety and longevity in industrial applications.

Technical Data

Specification Details
Operating Voltage UB 24 VDC +60% –5%
Operating Range
  • Upper Limit Value uB(t)max: 39 V
  • Lower Limit Value uB(t)min: 22 V
Power Consumption PS < 50 VA
Current Consumption I < 1 A (with loading current)
Fuse I S 2.5 A slow
Inputs
  • Command Values 1 to 4 Ue ±9 V (reference potential is M0)
  • Command Value 5 Ue ±6 V (reference potential is M0)
  • Command Value 6 (Differential Input) Ue 0 to ±10 V; Re = 100 kΩ
Outputs Details
Output Stage - Solenoid
  • Maximum Solenoid Current/Resistance: Imax 800 mA; R(20) = 19.5 Ω
  • Biasing Current: IV 20 mA ±25%
  • Pulse Frequency: f 170 Hz ±10%
Regulated Voltage U ±9 V ±1%; ±25 mA externally loadable
Measuring Sockets - Current Command Value "W" U ±6 V; Ri = 5 kΩ
Measuring Sockets - Current Actual Value "IA" and "IB" UA; UB 0 to 800 mV equivalent 0 to 800 mA