Indramat VPB

Indramat VPB

The IndraControl VPB is a line of industrial box PCs designed for applications where there is a need to separate the PC and control units. These PCs are intended to be mounted in control cabinets and connected to various displays and terminals. They are available in different versions to meet various industry requirements, offering a range of specifications particularly in terms of computing power, storage capacity, and expansion options with plug-in cards. The technical data provided indicates three different slots or versions (Slot 1, Slot 2, and Slot 4) with four CPU options available for each: Celeron P4500 1.86 GHz, Core i5-520M 2.4 GHz, Core i7-620M 2.66 GHz, and Core i7-3612QE 2.1 GHz. This variety ensures flexibility and scalability to accommodate diverse industrial applications.

Processor VPB 40.3 Slot 1 VPB 40.3 Slot 2 VPB 40.3 Slot 4
CPU Celeron P4500 1.86 GHz
Core i5-520M 2.4 GHz
Core i7-620M 2.66 GHz
Core i7-3612QE 2.1 GHz
Celeron P4500 1.86 GHz
Core i5-520M 2.4 GHz
Core i7-620M 2.66 GHz
Core i7-3612QE 2.1 GHz
Celeron P4500 1.86 GHz
Core i5-520M 2.4 GHz
Core i7-620M 2.66 GHz
Core i7-3612QE 2.1 GHz
Operating System Windows XP Windows XP Windows 7

Hardware Data

Hardware PCI/PCIe slots Hard disk Hard disk (RAID 1) Solid State Disk SSD DVD-ROM/DVD-RW Memory Use / application
1/0 1 x 320 GB (Standard) 2 x 320 GB (Option) 192 GB (Option) 2 GB
2/0; 1/1 1 x 320 GB (Standard) 2 x 320 GB (Option) 192 GB (Option) DVD burner (Option) 2 GB
4 GB
4/0; 2/2; 0/4 1 x 320 GB (Standard) 2 x 320 GB (Option) 192 GB (Option) DVD burner (Option) 2 GB
4 GB
8 GB

Electric Specifications

- Power supply voltage (U): 24 V DC
- Voltage range (Umin - Umax): 19 V DC to 30 V DC
- Power consumption: 160 W
- UPS: External

Ambient Conditions

Protection IP20
Load Vibration resistance: 1 g
Shock resistance: 15 g
Norms and Standards Certification: CE/UL/CSA
Environmental conditions Permissible temperature (operation): +5 °C ... +45 °C