Skip to content
Call:1-888-551-3082 International: 1-919-443-0207 sales@servosupplier.com
Call:1-888-551-3082 International: 1-919-443-0207 sales@servosupplier.com

Indramat HCQ

Indramat HCQ Motors

The IndraDyn L motor's primary part is designated as MLP, a term that signifies its critical role in the motor's function. The motor size is determined by the width of the active magnet in the secondary part of the motor, which also corresponds to various power ranges offered by the motor. Motor lengths within a given series increase in size and are differentiated by alphabetical ID letters, such as A, B, or C, which represent frame lengths. Additionally, the winding code numbers provide an indication of the maximum speed that the motor can achieve, expressed in meters per minute (F_max). All primary parts of IndraDyn L motors are equipped with liquid cooling systems for operation, making liquid cooling the sole cooling option available for these motors, ensuring efficient heat dissipation during their use.

HCQ Type Code Breakdown

Below is an example of how to read the HCQ

- Product: HCQ
- Line: 02
- Design: 1
- Power Supply: Feeding - E
- Cooling Mode: Air, internal (through integrated blower) - W
- Rated Power: e.g. 25 kW - 0025
- Degree of Protection: IP20 - A
- Mains Connecting Voltage: 3 x AC 200...500 V +10% - 03
- Control Section Design: Basic - B
- Master Communication: Embedded PC, LX 800. - L8
- Interfaces:
- Encoder: 5
- Probe: 4
- Digital Inputs: 32
- Digital Outputs: 16
- SERCOS III Master: ×
- Code: 1S
- Option 1: Without. - NN / DEA40.1 - D1
- Option 2: Without. - NN / DEA40.1 - D1
- Other Design: Without. - NN
- Firmware: Denotes that firmware must be ordered as separate subposition - FW / Without firmware. - NW

Ambient Conditions

Description Symbol Unit Value
Conductive dirt contamination - - Not allowed
Protection degree of the device (IEC 60529) - - IP20
Use within the scope of CSA / UL - - For use in NFPA 79 applications only.
Temperature during storage - - -25 ... 55 Celsius
Temperature during transport - - -25 ... +70 Celsius
Allowed mounting position - - G1
Installation altitude henn m 1000
Ambient temperature range Ta_work °C 0 ... 40
Temperature range Ta_tran °C Supply units and drive controllers: -25 ... +70
Motors: -20 ... +80
Relative humidity - % 5 ... 95
Absolute humidity - g/m3 1 ... 60
Climatic category (IEC 721) - - 2K3
Moisture condensation - - Not allowed
Icing - - Not allowed