Skip to content
Call:1-888-551-3082 International: 1-919-443-0207 sales@servosupplier.com
Call:1-888-551-3082 International: 1-919-443-0207 sales@servosupplier.com

CSH01.3C-NN-EN1-MA1-CCD-NN-S-NN-FW

Request a quote
The Bosch Rexroth Indramat CSH01.3C-NN-EN1-MA1-CCD-NN-S-NN-FW is an advanced control section with a single-axis operation. It is not compatible with the manufacturer's comfort control panel but contains an EN1 optional module suitable for encoder systems with an 8VDC or 18.2VDC peak-to-peak supply voltage. The unit includes two Type 2 probe inputs and must not operate without its associated drive controller. Use of this section necessitates adherence to operating, maintenance and safety guidelines, and repairs should only be done by authorized personnel. The device features a 100Base-TX compatible cross-communication module following Ethernet and IEEE 802.3u standards and includes a 15-pin female D-Sub connector for higher resolution analog channels. The unit's installation must adhere to the application's EMC requirements and should be disconnected from the power supply when repairing components with over 50V voltage potential. Global shipping is available for this product.
30 Day Warranty
Technical Specifications
  • Manufacturer: Bosch Rexroth Indramat
  • Product Code: CSH01.3C-NN-EN1-MA1-CCD-NN-S-NN-FW
  • Control Section Type: Single Axis Advanced Control Section
  • Comfort Control Panel Compatibility: Not compatible
  • Optional Module: EN1 compatible with encoder systems with supply voltage 8VDC or 18.2VDC
  • Operational Environment: Not allowed underwater
  • Probe Inputs: Type 2, 24V voltage rating and a 3mA current rating
  • Usage Requirement: Cannot be used without the related drive controller
  • Digital Outputs Usage: Cannot be used at low-resistance sources
  • Cross-Communication Module: Ethernet standards, 100Base-TX compatibility, IEEE 802.3u standards
  • Safety Technology Module: Not included
  • Encoder Evaluation: Supports resolver and HSF encoder evaluation
  • Additional Module: MA1, connected by a 15-pin female D-Sub connector, provides better resolution analog channels
  • Interface: RS 232 Serial interface
  • Installation Requirement: Must be done according to the appropriate EMC requirements
  • Safety Requirement: Must be removed from the connected power supply with more than 50V voltage potential before accessing its components
  • Shipping: Global