CSH01.3C-NN-EN2-MEM-CCD-L2-S-NN-FW

Request a quote
The CSH01.3C-NN-EN2-MEM-CCD-L2-S-NN-FW is a compact, advanced control section produced by Bosch Rexroth Indramat. Specifically configured and combined with designated components, it should not operate with its grounding conductor disconnected. The risk of dangerous movement is present if the motor's input parameters are misconfigured. A characteristic feature of the unit is its vertical axis, which must be secured against falling after power supply disconnection. It includes an MEM optional module for encoder emulation and generates incremental plus absolute value signals for review. The unit conforms to IEC 61800-3 specifications and doesn't tolerate salt mist or condensation. The device can accept two conductors in a single terminal point and connects with screw terminal blocks with appropriate ferrules. It employs the HAS05.1-003 signal level converter to adjust output voltage in the 5V to 30V range. The control section comes with a one-year backup support.
30 Day Warranty
Technical Specifications
  • Manufacturer: Bosch Rexroth Indramat
  • Product Code: CSH01.3C-NN-EN2-MEM-CCD-L2-S-NN-FW
  • Size: Smaller than power section of the drive controller
  • Operating Condition: Must operate only in the specified configuration
  • Safety Requirement: Must have a permanent connection of its equipment grounding conductor
  • Danger: Device-associated dangerous movement during wrong input parameters
  • Specification: One vertical axis secured against falling after disconnecting power supply
  • Mode: Must be in standstill mode before accessing danger zone
  • Feature: MEM optional module that offers encoder emulation
  • Compatibility: Cannot be connected with components not specifically named
  • Restriction: Should not be used if maximum temperature is too high
  • Component Category: Category C3 components feature restricted distribution in accordance to IEC 61800-3 specifications
  • Condition: Must never have salt mist or condensation on surface
  • Shipping: Supports international shipment
  • Pulse Width: Maximum of 100ms
  • Inrush Current Rating: Typical of 4A
  • Connection: Allows connection of two conductors to a single terminal connecting point using TWIN ferrules or wires of same cross-section
  • Shielding: MEM module must be connected with double shielding lines to avoid damage
  • Terminal Block Connection: Supports screw terminal blocks with wire ends featuring ferrules and appropriate crimping tools
  • Voltage Adjustment: HAS05.1-003 signal level converter adjusts voltage level at output of MEM module to 5V to 30V range
  • Backup Support: One year