Skip to content
Call:1-888-551-3082 International: 1-919-443-0207 sales@servosupplier.com
Call:1-888-551-3082 International: 1-919-443-0207 sales@servosupplier.com

CSB01.1C-PB-ENS-MA1-NN-S-NN-FW

Request a quote
The CSB01.1C-PB-ENS-MA1-NN-S-NN-FW, offered by Bosch Rexroth Indramat, supports two types of PFM02.1 multimedia memory cards for easy transmission of parameters. With two current control, velocity control, and position control cycle times, it has screw terminal blocks and spring terminals at connection points. Capable of connecting two conductors at one point, it is recommended to use wire ends without ferrules. This control section features an inrush current of 4.5A and prohibits hot-plugging, requiring to disconnect before turning on the drive controller. With optional modules PB, ENS, and MA1 rated at 2W, 6W and 2W power consumption, it performs multiple functions including setting drive address and diagnosing errors. Although it lacks safety options, this compact control section must be installed and operated by trained personnel. It includes capacitors that continue to operate half an hour post disconnecting power supply. A separate subitem is required to purchase its firmware. Lastly, it features a PROFIBUS module connection with a metalized connector housing and D-Sub mounting screws.
30 Day Warranty
Technical Specifications
  • Manufacturer: Bosch Rexroth Indramat
  • Product Code: CSB01.1C-PB-ENS-MA1-NN-S-NN-FW
  • Media Memory Card Support: Two types of PFM02.1 cards
  • Control Cycle Times: Two current control, velocity control and position control
  • Connection Points Details: Screw terminal blocks and spring terminals
  • Inrush Current: 4.5A
  • Power Connection: Cannot be hot plugged
  • Functions: Drive address setting, Basic loads default procedure, Error memory diagnostics, Position data reference
  • Power Consumption: PB module: 2W, ENS module: 6W, MA1 module: 2W
  • Safety Feature: Not available
  • Configuration Option: Available
  • Size: Smaller than the power section of a drive controller
  • Installation and Operation: Only by trained personnel
  • Discharge Time: Up to half an hour after the power supply is disconnected
  • Firmware: Has to be procured separately
  • Connection Type: PROFIBUS module connection with a metalized connector housing and D-Sub mounting screws for shield connection.

Get In Contact

Email: sales@servosupplier.com


Phone Number: 1-888-551-3082


International: 1-919-443-0207

Fax: 1-919-867-6204