Skip to content
Call:1-888-551-3082 International: 1-919-443-0207 sales@servosupplier.com
Call:1-888-551-3082 International: 1-919-443-0207 sales@servosupplier.com

CSH01.1C-ET-EN2-NNN-MA1-S2-S-NN-FW

Request a quote
The CSH01.1C-ET-EN2-NNN-MA1-S2-S-NN-FW is an advanced control section produced by Bosch Rexroth Indramat. It features a design code 1 and does not support operation with the VCP01.2 comfort control panel. Notable for its Multi-Ethernet interface that communicates using shield ITP cables and complies with CAT5e standards, the unit employs a standard 8-pin RJ-45 connector for Ethernet functionality. Its EnDat 2.1 / 1Vpp / TTL encoder with a 5.25V DC output and 350mA rating enables interface encoder evaluation. The product can be programmed for two current controls, position controls, and velocity controls. It is also compatible with different switching frequencies from 2kHz up to 16kHz. The control section pairs with the manufacturer’s drive controller to regulate the associated electric motor's operation and requires only conductive packaging for storage and transport. Its usage necessitates adherence to specified operating conditions, official accessories, and involves high voltage and current. Only qualified personnel should handle the unit, especially when powered.
30 Day Warranty
Technical Specifications
  • Manufacturer: Bosch Rexroth Indramat
  • Product Code: CSH01.1C-ET-EN2-NNN-MA1-S2-S-NN-FW
  • Design Code: 1
  • Ethernet Interface: Multi-Ethernet interface with standard 8-pin RJ-45 connector
  • Cables: Shield ITP cables as per CAT5e specifications
  • Encoder: EnDat 2.1 / 1Vpp / TTL encoder
  • DC Output Voltage: 5.25V
  • Output Current Rating: 350mA
  • Control Types: Two current control, position control, velocity control cycle times
  • SERCOS Cycle Time: One minimum
  • Switching Frequencies: Ranges from 2kHz to 16kHz
  • Compatibility: Works with the manufacturer’s drive controller
  • Packaging: Transported and stored in conductive packaging
  • Touch Restrictions: Must not contact exposed conductive parts that are not discharged by grounding
  • Shipping: Can be sent worldwide through reputed freight carriers
  • Operating Conditions: Must not be used outside the specified conditions
  • Spare Parts and Accessories: Should only use approved ones
  • Electric Current and Voltage: Can be high if used inappropriately
  • Surface Heat: Can be very hot during operation
  • Operation and Maintenance: Must be done by trained and qualified personnel
  • Electrical Connection Points: Not to be touched when the power is turned ON.